DEVICE
Medtronic ePID 2.0
Closed loop system is an automated insulin delivery system based on body blood sugar. It consists of an Insulin pump, glucose sensor, and a device presently a laptop with all the algorithms.
Status
Completed
Phase
Phase 1
Enrollment
13
Locations
1
Results
Not posted
Publications
0
Study summary
Post-prandial hyperglycemia occurs despite meticulous carbohydrate counting and rapid acting insulin therapy. Furthermore, this occurs even in the setting of the closed loop system. Currently the algorithm used for calculating the glucose-responsive insulin delivery cannot respond in a timely fashion to the glucose absorption resulting from a meal. In diabetes, there is paradoxical immediate post-prandial hyperglucagonemia that results in immediate post-prandial hyperglycemia. Amylin deficiency and/or dysregulated GLP-1 seems to be the etiology. Pharmacologic replacement of these hormones alleviates immediate post-prandial hyperglycemia in diabetes. With this protocol, the investigators would like to optimize treatment of T1DM by physiologic replacement of hormones in addition to insulin and in the process also optimize the insulin algorithm. This is a paired, randomized, and controlled comparison of pramlintide and insulin versus exenatide and insulin Vs insulin monotherapy using the ePID closed-loop system for insulin delivery. The investigators will stratify the study subjects into the following sub-groups of 5 subjects of 22-30 years old, 4 subjects of 18-21 years old, 4 subjects of 16-18 years old. The investigators would also begin the study with the 21-25 year patient sub-group and then transition to the other sub-groups after evaluating all the safety issues. 22-30 year old ones would be considered as an adult subset, 18-21 year olds would be considered pediatric subset according to the guidelines of FDA's Center for Devices and Radiological Health (CDRH) and 16-18 year olds are considered typical pediatric population. At this time, Spanish-speaking subjects will not be recruited because Medtronic Minimed as yet does not have any literature in Spanish that may used in explaining the study to this group of patients. When in the future Medtronic is able to provide us with the appropriate Spanish literature, the investigators will at that time amend the protocol to include this group of subjects.
Diabetes complications can be minimized or forestalled with the use of intensive insulin management. In the post-Diabetes Control and Complications Trial (DCCT) era, diabetologists around the globe are engaged in developing better methods of improving glycemic control in patients with type 1 diabetes mellitus (T1DM). To achieve the DCCT-recommended glycemic and hemoglobin A1C (HbA1c) goals, in addition to physicians, engineering and pharmaceutical companies are augmenting our ability to improve control by innovative compounds and technologies such as continuous glucose monitoring. Despite these substantial advances, hyper- and hypoglycemia continue to be problematic in the management of T1DM, especially in children. Current T1DM management involves checking blood glucose pre-prandially and once at bedtime (4 times/day), and making insulin dose adjustments based on these 4 blood glucose measurements. This approach is woefully inadequate. Post-meal hyperglycemia is missed, and low blood glucose is undetected until the patient has symptomatic hypoglycemia. Moreover, we depend on patients to make appropriate dose modifications to basal rates of insulin when on the pump, without the guidance of adequate blood glucose measurements. The continuous glucose monitoring system (CGMS) is increasingly studied as a tool to examine glucose trends, and is helping to combat inadequate self-monitoring. However, the CGMS still relies on the patient's ability to make accurate insulin dose adjustments based on glucose readings. To address this issue the closed loop system is now under investigation. The closed loop system is developed to closely emulate physiologic insulin delivery. The algorithm was developed by modeling beta cells and validated by hyperglycemic clamp studies using the subcutaneous site for measurement of blood glucose and insulin delivery. The algorithm is known as the external Physiologic Insulin Delivery (ePID). Current studies suggest that basal requirements are detected accurately, and the algorithm responds effectively. However, meal related elevation in blood glucose remains a challenge, as when blood glucose levels begin to rise and are seen in the subcutaneous glucose sensor signal, it is already too late to administer insulin in a way that will effectively minimize the postprandial glucose peak. Improvements in the ePID algorithm have been studied to improve the postprandial response with some success, but require user intervention for best results, and despite that glucose excursions fail to normalize in the post-prandial period. It is likely that further improvements in postprandial glycemia will be limited with insulin monotherapy. Besides insulin there are other dysregulated hormones such as glucagon and amylin, which contribute to post-prandial hyperglycemia. The autoimmune destruction of insulin-secreting beta cells of the pancreas is presumed to cause T1DM. In addition to insulin, other hormones such as glucagon and amylin play a role in normalizing glucose excursions. Failure of glucagon suppression results in immediate postprandial hyperglycemia, and a loss of glucagon response to hypoglycemia results in late postprandial hypoglycemia. Despite the increasing use of subcutaneous continuous insulin administration and newer insulin analogs, insulin replacement remains imperfect, and glucose excursions are inadequately controlled in diabetes. This suggests that other factors, in addition to diet and insulin management, may need to be addressed if postprandial glucose excursions are to be normalized in T1DM. The recent discovery of the hormone amylin has enhanced our understanding of postprandial glucose homeostasis. Patients with T1DM have deficiencies of both insulin and amylin. Amylin, a 37-amino acid polypeptide hormone, is co-secreted from the pancreatic beta cells in conjunction with insulin in response to nutrient stimuli. Amylin, in the immediate postprandial period, may mediate part of its effect by suppressing glucagon secretion, resulting in the suppression of hepatic glucose production and the slowing of gastric emptying. Pramlintide acetate is a synthetic analog of the naturally occurring human hormone amylin. It effectively reproduces amylin agonist activity in an equipotent fashion. Pramlintide acetate has been reported to improve glycemic control in adults with both type 1 and type 2 diabetes mellitus. Specifically, postprandial glucose excursions are improved with adjunctive pramlintide use compared with insulin monotherapy. Exenatide is a synthetic analog of exendin-4. It is FDA approved for use in adults with type 2 diabetes mellitus (T2DM). Clinical studies indicate that exenatide is very effective in decreasing postprandial glucose excursions. The investigator's brochure for exenatide suggested that in adults with T2DM, exenatide was well tolerated at 0.1 mcg/ kg/ dose, and resulted in glucose lowering. Our preliminary data in children with T1DM suggests that 1.25 mcg and 2.5 mcg are good pre-prandial initial doses with a prandial insulin dose reduction of 30%. The principal mechanism of action in T1DM is suppression of glucagon, with a subsequent suppression of hepatic glucose production and decreased immediate post-prandial hyperglycemia. These effects result in further reduction of HbA1c beyond the reduction observed with insulin alone. Additionally, in T2DM, exenatide delays gastric emptying, and decreases food intake through centrally mediated mechanisms causing satiety and improved weight control. The most notable adverse effect of exenatide is nausea, which improves with the duration of treatment and steady dose escalation of exenatide. Hypoglycemia may occur with concurrent use of insulin. In the current exploratory studies we are proposing a novel way to combat immediate postprandial hyperglycemia in subjects with T1DM by using the study medications through the experimental closed loop system. Subjects will not be on the closed loop system prior to eligibility, and would not have used the closed loop system at an earlier time. We will use prandial pramlintide/exenatide in the first protocol, and test the hypothesis that this intervention will be superior to using insulin monotherapy in the closed loop system. This would be a Biologic, phase I, single center study and a paired, randomized, and controlled comparison of pramlintide and insulin versus exenatide and insulin Vs insulin monotherapy using the ePID closed-loop system for insulin delivery. We will stratify the study subjects into the following sub-groups of 5 subjects of 22-30 years old, 4 subjects of 18-21 years old, 4 subjects of 16-18 years old. We would also begin the study with the 22-30 year patient sub-group and then transition to the other sub-groups after evaluating all the safety issues. 22-30 year old ones would be considered as an adult subset, 18-21 year olds would be considered pediatric subset according to the guidelines of FDA's Center for Devices and Radiological Health (CDRH) and 16-18 year olds are considered typical pediatric population. At this time, Spanish-speaking subjects will not be recruited because Medtronic Minimed as yet does not have any literature in Spanish that may be used in explaining the study to this group of patients. When in the future Medtronic is able to provide us with the appropriate Spanish literature, we will at that time amend the protocol to include this group of subjects. Study Procedure: Screening: Screening evaluations will be performed 1-2 months prior to study enrollment, and will consist of an informed consent, medical history, physical examination (including height, weight, and vital signs), and blood samples for clinical laboratory tests. The clinical laboratory tests will include a CBC to check for anemia, hemoglobin A1C (within last month), serum electrolytes, serum amylase, Serum HCG pregnancy test for female subjects. The approximate volume of blood is expected to be less than 5 ml. Following informed consent (and with appropriate subject assent) if subject is found eligible for the study, they will undergo a baseline open-loop evaluation using a Medtronic Data logger continuous glucose monitor (Medtronic Diabetes, Northridge, CA). The data on glucose excursions will be collected on their usual insulin dosages so as to appropriately configure the algorithm of the closed-loop system during the inpatient admission. Basal rates and insulin to carbohydrate ratios will be adjusted during the period between screening and the start of the 3 studies that they will undergo subsequently. After screening, subjects will undergo a 3-period crossover design trial in random order. Study A Subjects will be admitted to the general clinical research center (GCRC) on the evening prior to the study at 6 PM. For female subjects a stat serum HCG pregnancy test is done prior to the start of the study. Two sensors will be placed in the subcutaneous tissue. Insertion of IV line will occur between 9-10 PM. During the night hourly samples of blood glucose will be used to adjust insulin basal or boluses so as to maintain euglycemia. Around 6 a.m. subjects will be started on the closed-loop system for the automated delivery of insulin based on the glucose sensor measurements. An intravenous line will be inserted in the antecubital fossa to maintain blood glucose concentrations within the normal range. Blood samples for basal glucose, insulin, and glucagon concentrations will be drawn at minus 30, minus 10, and 0 min prior to study start. For study A (Control): Subjects will receive meals at 0 minutes (approximately 7 AM breakfast), 300 min (approximately Noon lunch) and dinner at 600 min (approximately 5 PM dinner). A partial bolus of insulin will be administered prior to breakfast in addition to closed loop system (since the system is not expected to have calibrated by the time of breakfast). For study B: Subjects will receive 30 mcg of pramlintide just before 300…
Interventions
DEVICE
Closed loop system is an automated insulin delivery system based on body blood sugar. It consists of an Insulin pump, glucose sensor, and a device presently a laptop with all the algorithms.
Timeline
First posted
Jan 4, 2011
Study start
Dec 2010
Primary completion
Jan 2013
Study completion
Jan 2013
Results posted
Not reported
Registry updated
Feb 20, 2018
Outcomes
Better meal and post meal sugars on the closed loop device using the study medications.
Time frame · 18 months
We will assess the preliminary data collected from the subjects enrolled by that time
Not reported in the indexed record.
Eligibility
Inclusion Criteria: 1. Age greater than 18 years and less than 30 years. 2. Have had diabetes for at least 1 year, and in good control (HbA1C less than 8.5 %). 3. Be on continuous subcutaneous insulin infusion using an insulin pump 4. Subjects must be otherwise healthy except for T1DM, and treated for hypothyroidism if present 5. Menstruating women must have negative pregnancy test. 6. Hemoglobin (Hb) more than 12 g/dl 7. Weight must be equal to or greater than 50 Kg Exclusion Criteria: 1. Any chronic disease (leukemia, asthma, inflammatory bowel disease, cystic fibrosis, juvenile rheumatoid arthritis, etc that directly, or as a result of treatment, directly or indirectly affect glucose homeostasis). 2. Hemoglobin less than 12 g/dl 3. Lack of a supportive family environment 4. Positive pregnancy test based on serum beta HCG in menstruating young women 5. Evidence or history of chemical abuse 6. HbA1c more than 8.5 % 7. Weight less than 50 Kg 8. History of gastroparesis and on medications that alter gastric emptying 9. History of Pancreatitis and impaired renal function 10. Hypoglycemic unawareness 11. History of sensitivity to 5-HT3 receptor antagonists 12. History of QT prolongation 13. Concomitant use of both Acetaminophen and vitamin C 14. Patients on glucocorticoid therapy 15. Known allergies to any of the study medication
Study locations
United States. Showing up to 24 locations stored in the fast local snapshot.
Albert Einstein College of Medicine CRC
The Bronx, New York, United States
Publications
No PMID-linked publications were present in this registry snapshot.
Related trials
University of Copenhagen · Healthy Adult Participants · Bone Physiology
Not applicable
Not yet recruiting
15
2026-07
Oregon Health and Science University · Type 1 Diabetes
Not applicable
Completed
33
2026-06
Boston University · Alzheimer Disease · Mild Cognitive Impairment
Early Phase 1
Active, not recruiting
57
2026-05
Esbjerg Hospital - University Hospital of Southern Denmark · Obesity · Appetite Regulation
Phase 2 / Phase 3
Withdrawn
0
2026-04
University Hospital, Gentofte, Copenhagen · Obesity & Overweight
Not applicable
Recruiting
18
2026-04
Danish Headache Center · Headache Disorders, Secondary · Brain Diseases
Not applicable
Not yet recruiting
21
2026-01
Danish Headache Center · Headache Disorders, Primary · Headache Disorders
Not applicable
Not yet recruiting
21
2026-01
McGill University Health Centre/Research Institute of the McGill University Health Centre · type1diabetes · Diabetes Mellitus, Type 1
Phase 2 / Phase 3
Unknown
30
2024-04